Jiangsu Zhongchao Cable Corporation
Products
Contact Us
  • Contact Person : Mr. Huang Tony
  • Company Name : Jiangsu Zhongchao Cable Corporation
  • Tel : 86-0510-87698158
  • Fax : 86-0510-87693777
  • Address : Jiangsu,wuxi,NO.999 ZHENFENG EAST ROAD, XIJIAO INDUSTRIAL PARK, YIXING CITY
  • Country/Region : China
  • Zip : 214242

XLPE Insulated power cable

XLPE Insulated power cable
Product Detailed
Related Categories:Power Cables

Detailed Product Description


XLPE insulated power cable
Cross-linked polyethylene power cable is simply named XLPE power cable. This product is used for power device with 35KV AC rated voltage and below or electric circuit to transfer electric circuit. XLPE insulated power cable has excellent mechanical performance, electric performance and anticorrosive performance. Besides, it also has the advantages of simple structure, small outer diameter, light weight, unrestricted laying, and convenient transportation and so on, so it is widely used in electric power, metallurgy, chemical industry and urban grid construction.

Executive standard

GB12706.3-2002 and IEC60502-1997

And it can also be designed and manufactured according to the standard of BS, VDE and ICEA recommended by International Electro technical Commission as per users requirements.

XLPE power cable : Voltage, Core and Section size   
Voltage range0.6/1-26/35KV  
Cross-section1.5-800mm2
Core1-5 core     

   Rated Kv               

Core

Type 1

0.6/1

1.8/3

3.6/6

6/10

8.7/15

12/20

18/30

21/35

Type 2

1/1

3/3

6/6

8.7/10

12/15

18/20

 

26/26

1

 

1.5-800

10-800

25-800

25-800

50-800

50-800

50-800

50-800

2

1.5-240

10-240

----

-----

-----

-----

-----

-----

3

1.5-400

10-400

25-630

25-630

25-630

50-630

50-630

50-630

4

1.5-500

10-500

-----

-----

-----

-----

-----

-----

3+1

1.5-500

10-500

-----

-----

-----

-----

-----

-----

5

1.5-500

10-500

-----

-----

-----

-----

-----

-----

Note: Type 1 is suitable for three-phase system whose earth fault continuous time is not over 1 min every time.,
Type 2 is suitable for three-phase system whose earth fault continuous time is not over 2 hours every time. At most , not over 8 hours.
 

Main parameters and laying requirement
(1) D.C. resistance: When 20, the R of every kilometerΩ/km should not be over the rule
(2)Voltage test: Under ambient temperature,conductor apply with 3.5Uo power frequency voltage for the earth. After 5 minutes, disruptive needed.
(3) partial discharge testAS for 3.6/6KV and more, when applying 1.73Uo between conductor and metal shield,partial discharge not over 5Pc.
(4) Max. short circuit temperature of conductor shall not exceed 250(5s maximum duration ).
The ambient temperature should not below 0 when installation
The bending radius should not less than 15 times of cable diameter



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.